Description
1.1 This specification covers ASTM Specification A416/A416M low-relaxation Grade 250 and Grade 270 seven-wire prestressing steel strand with protective fusion-bonded epoxy coating applied by the electrostatic deposition method or other method that will meet the coating requirements in Section 8, and, except as allowed by 1.2, with the interstices of the seven wires filled with epoxy to minimize migration of corrosive media, either by capillary action or other hydrostatic forces.
Note 1 – The manufacturer as identified throughout this specification is the coating applicator.
1.2 Upon special request by the purchaser, the interstices are left unfilled.
Note 2 – Unfilled strand can corrode from the inside and its application for prestressing tendons in concrete or for rock and soil anchors is not recommended.
1.3 This specification is applicable for orders in either inch-pound units (as Specification A882) or SI units [as Specification A882M].
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
Product Details
- Published:
- 05/01/2010
- Number of Pages:
- 5
- File Size:
- 1 file , 100 KB
- Redline File Size:
- 2files, 190 KB