Description
Describes a passenger-train air conditioning system that controls indoor air temperature according to the thermal comfort index, the PMV (predicted mean vote). Mean radiant temperature, air humidity and outdoor temperature are monitored in order to calculate the set temperature at which the PMV index becomes zero. The set temperature is maintained by using the fuzzy control method to adjust the operation of the air conditioner compressors. Notes that results obtained with a fuzzy control simulator show that the proposed control system keeps the indoor PMV near zero, where the thermal sensation of the passengers is expected to be neutral.
KEYWORDS: year 1995, Air conditioning, controls, thermal comfort, indoor, air temperature, fuzzy logic, transport, trains
Citation: ASHRAE Trans. 1995, Vol.101, Part 1, Paper number 3870, 423-430, 12 figs, 3 tabs, refs.
Product Details
- Published:
- 1995
- File Size:
- 1 file , 700 KB
- Product Code(s):
- D-16744